Home
Concrete Repair, EucocretePMC - Accepted for Use  
Normal setting one part repair material, high early strength, high strength, aggregate addable, repair for horizontal and form and pour applications from 20mm (3/4") to 150mm (6"). Working time up to 1 hour. Slump 200mm (8") to 250mnm (10").

Brand Name: Euclid Eucocrete
Manufacturer: Euclid Admixture Canada Inc.   
Categories: Structures and Structural | Concrete | Patching | Non-Structural
Structures and Structural | Concrete | Patching | General Repairs
Structures and Structural | Concrete | Patching | High Strength
Structures and Structural | Concrete | Patching | Vertical
Structures and Structural | Concrete | Patching | Horizontal
Structures and Structural | Concrete | Patching | Working Time | > 15 Minutes
Structures and Structural | Concrete | Patching | Aggregate Extendable
Pavements | Concrete | Restoration | Concrete Patching

Contacts

Brian Salazar, C.E.T., LEED® AP
National Business Development Manager
Euclid Admixture Canada Inc.
90 Millwick Dr
Toronto, ON    M9L 1Y3
Canada
Phone: 416-747-7107(Toll Free)
Fax: 416-747-9970
Office: 877-210-4442
Email: b.salazar@euclidcanada.com
Web: http://www.euclidchemical.com
 
Standards Met
ASTM C1012-04  -  Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution
ASTM C109/C109M-08  -  Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
ASTM C1202-10  -  Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration
ASTM C157/C157M-08  -  Length Change of Hardened Hydraulic-Cement, Mortar, and Concrete
ASTM C266-08  -  Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
ASTM C348-08  -  Flexural Strength of Hydraulic-Cement Mortars
ASTM C403/C403M-06  -  Time of Setting of Concrete Mixtures by Penetration Resistance
ASTM C469-02e1  -  Static Modulus of Elasticity and Poisons's Ratio of Concrete in Compression
ASTM C496/C496M-04e1  -  Splitting Tensile Strength of Cylindrical Concrete Specimens
ASTM C531-00(2005)  -  Linear Shrinkage and Coefficient of Thermal Expansion of Chemical-Resistant Mortars, Grouts, Monolithic Surfacings, and Polymer Concretes
ASTM C666/C666M-03(2008)  -  Resistance of Concrete to Rapid Freezing and Thawing
ASTM C882-05e1  -  Bond Strength of Epoxy-Resin Systems Used With Concrete By Slant Shear
Concrete Patching Materials  -  List of Proprietary Concrete Patching Materials
MI-67  -  A Laboratory Evaluation of Concrete Patching Materials
OPSS 930 (Replaced by MTO SP 109S50 for MTO Contracts)  -  Structure Rehabilitation - Concrete Patches and Overlays
SP 109S50 (Replaces OPSS 930, May 1994 for MTO Contracts)  -  AMENDMENT TO OPSS 930, MAY 1994 - Construction Specification for Structure Rehabilitation - Concrete Patches, Refacing and Overlays
SP 999S10  -  CONCRETE PATCHES, PROPRIETARY PRODUCTS - Material and Construction Requirements